Porter-cable H450CS User Manual Page 14

  • Download
  • Add to my manuals
  • Print
  • Page
    / 20
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 13
14 — ENG
MAINTENANCE
Note 1: Change oil after first two (2) operating hours and every 50 operating hours thereafter, more often if operated in
extreme dusty or dirty conditions.
Note 2: Check oil after 5 hours of operation
CUSTOMER RESPONSIBILITIES TABLE
MAINTENANCE TASK
Before each
use
X
Every 25
Hours or Every
Season
See Note 2
X
Every 50
Hours or Every
Season
See Note 1
Every 100
Hours or Every
Season
X
Check oil level
Change oil
Clean Air Filter Assembly
Check Spark Plug
Prepare Unit for Storage
Prepare unit for storage if it is to remain idle for more than 30 days.
CONNECTING PROCEDURE FOR RAISING OR
SUSPENDING GENERATORS (H650CS)
Failure to properly connect lifting cables, chains,
or straps can cause property damage, serious
injury or death, and void the manufacturer's
warranty.
Always use cables, chains, or straps rated at 2000
lbs. working load or more to raise or suspend gen-
erator.
Never operate generator while suspended. This
could cause property damage, serious injury or death.
Lift Ring
Lift Ring
1. Route cable, chain, or strap through both lift rings as
shown. ALWAYS use both lift rings when raising or
suspending generator.
Make sure the generator is in a level position
before raising or suspending to prevent damage.
GENERAL RECOMMENDATIONS
The warranty of the generator does not cover items that
have been subjected to operator abuse or negligence.
To receive full value from the warranty, operator must
maintain the generator as instructed in this manual.
ENGINE MAINTENANCE
Refer to the Engine Operator's manual for service and mainte-
nance of the engine.
Page view 13
1 2 ... 9 10 11 12 13 14 15 16 17 18 19 20

Comments to this Manuals

No comments