PROBLEM
CAUSE CORRECTION
TROUBLESHOOTING GUIDE
Engine will not start
No electrical output
Repeated circuit breaker
tripping
Generator overheating
1. Low on fuel or oil.
2. Ignition switch in "Off" position.
3. Faulty spark plug.
4. Choke in wrong position.
5. Fuel shut-off valve in closed
position.
6. Unit loaded during start-up.
7. Spark plug wire loose.
1. Faulty receptacle.
2. Circuit breaker kicked out.
3. Defective capacitor.
4. Faulty power cord.
5. GFCI switch breaker kicked out.
1. Overload
2. Faulty cords or equipment.
1. Generator overloaded.
2. Insufficient ventilation.
1. Add fuel or oil.
2. Turn to "ON" position
3. Replace spark plug.
4. Adjust choke accordingly.
5. Open fuel shut-off valve.
6. Remove load from unit.
7. Attach wire to spark plug.
1. Have Service Center replace.
2. Depress and reset.
3. Have Service Center replace
capacitor.
4. Repair or replace cord.
5. Depress and reset.
1. Reduce load.
2. Check for damaged, bare, or
frayed wires on equipment.
Replace.
1. Reduce load.
2. Move to adequate supply of
fresh air.
No auto idle
1. Faulty solenoid.
2. Faulty idle control switch.
3. Faulty windings in stator.
4. Faulty circuit board.
5. Faulty wire harness.
1. Have Service Center replace.
2. Have Service Center replace.
3. Have Service Center replace.
4. Have Service Center replace.
5. Have Service Center replace.
DC does not have power
with the circuit breaker
depressed
1. Faulty rectifier
2. Faulty windings in stator
3. Faulty wire harness
1. Have Service Center replace.
2. Have Service Center replace.
3. Have Service Center replace.