12 - ENG
If a nail becomes jammed in the nosepiece, keep
the tool pointed away from you and follow these
instructions to clear:
1. Disconnect the air supply from the tool.
2. Lift the canister door latch (E) to open the nail
guide door (H).
3. Open the canister door.
4. Remove the jammed nail.
5. Correct any deformation that may have occurred
to the nail coil.
 Should nails continue to jam frequently in nosepiece, have tool serviced by an
authorized PORTER-CABLE service center.

When operating tools at temperatures below freezing:
1. Make sure compressor tanks have been properly drained prior to use.
2. Keep tool as warm as possible prior to use.
3. Make certain all fasteners have been removed from canister.
4. Put 5 to 7 drops of PORTER-CABLE pneumatic tool oil in the air inlet.
5. Lower air pressure to 80 psi (5.5 bar) or less.
6. Reconnect air and load nails into canister.
7. Actuate the tool 5 or 6 times into scrap lumber to lubricate O-rings.
8. Turn pressure up to operating level (not to exceed 120 psi) and use tool as normal.
9. Re-lubricateatleastoncedaily.
10. Always drain the compressor tanks at least once a day.

Tool should operate normally. However, keep tool out of direct sunlight as excessive
heat can deteriorate bumpers, O-rings and other rubber parts resulting in increased
maintenance.

         
         


  
Lubricate tool with 5-7
drops of PORTER-CABLE
Pneumatic Tool Oil
Prevents failure
of o-rings
Insert drops into air fitting
on end cap of tool
Drain compressor tanks
and hoses daily
Prevents accumulation
of moisture in
compressor and nailer
Open petcocks or other
drain valves on compressor
tanks. Allow any accumulated
water to drain from hoses
