OilfreePortable Air CompressorInstructionmanualIMPORTANTPlease make certain that the person who isto use this equipment carefully reads andunderstands
10- ENGA01787Extension CordsUsing extension cords is not recommended. The use of extension cords willcause voltage to drop resulting in power loss to
11- ENGA01787Description of OperationBecome familiar with these controls before operating the unit.On/Auto/Off Switch (A): Turn thisswitch ON to provi
12- ENGA01787Cooling System (not shown): This compressor contains an advanced designcooling system. At the heart of this cooling system is an enginee
Before Starting Break-in instructionsSerious damage may result if the following break-ininstructions are not closely followed.This procedure is requi
How to Use Remote Console:When needed the remote console allows remote air regulation andcontrol closer to the work area.Reduce air pressure in tank t
15- ENGA01787How to transport unitThe unit has a handle (a) for carrying and a handle (b) for pulling.1. Grasp carrying handle (a) to lift unit.2. Sli
16- ENGA01787MAINTENANCECustomer ResponsibilitiesDaily oraftereachuseBeforeeachuse●●Yearly●11- more frequent in dusty or humid conditionsCheck Safety
17- ENGA01787Air Compressor Pump Intake and Exhaust ValvesOnce a year have a Trained Service Technician check the air compressor pumpintake and exhaus
18- ENGA01787To Replace or Clean Check Valve 1. Release all air pressure from air tank. See "To Drain Tank" in theMaintenance section.2. Unp
19- ENGA01787STORAGEBefore you store the air compressor, make sure you do the following:1. Review the "Maintenance" section on the preceding
2- ENGA01787SAFETY GUIDELINES - DEFINITIONSIndicates an imminentlyhazardous situationwhich, if not avoided, willresult in deathor serious injury.Indic
20- ENGA01787TROUBLESHOOTINGPerforming repairs may expose voltage sources, movingparts or compressed air sources, moving parts orcompressed air source
21- ENGA01787PROBLEMCAUSECORRECTIONIt is normal for "some"pressure drop to occur.If there is an excessiveamount of pressure dropwhen the acc
22- ENGA01787Regulator willnot shut off airoutlet.Damaged regulator.Replace.PROBLEMCAUSECORRECTIONMotor will notrun.Fuse blown, circuit breakertripped
23- ENGA01787NOTES
24- ENGA01787LIMITED WARRANTYPORTER-CABLE CORPORATION warrants to the original purchaser that all products covered under thiswarranty are free from de
3- ENGA01787IMPORTANT SAFETY INSTRUCTIONSSave these instructionsImproper operation or maintenance of this product could result in serious injury andpr
4- ENGA01787WARNING: Risk of BurstingAir Tank: The following conditions could lead to a weakening of the tank, and resultin a violent tank explosion a
5- ENGA01787WARNING: Risk to BreathingWARNING: Risk of Electrical ShockHAZARDHAZARDYour air compressor is powered byelectricity. Like any other electr
6- ENGA01787WARNING: Risk of BurnsTouching exposed metal such as thecompressor head or outlet tubes, canresult in serious burns.Never touch any expose
7- ENGA01787Review and understand all instructionsand warnings in this manual.Become familiar with the operation andcontrols of the air compressor.Kee
8- ENGA01787GLOSSARYBecome familiar with these terms before operating the unit.CFM: Cubic feet per minute.SCFM: Standard cubic feet per minute; a uni
9- ENGA01787INSTALLATIONHOW TO SET UP YOUR UNITGROUNDING INSTRUCTIONSRISK OF ELECTRICAL SHOCK. In the event of a shortcircuit, grounding reduces the
Comments to this Manuals