4. Remove arbor screw (E) Fig. 52, by turning screw
(E) clockwise while at the same time pressing in on arbor
lock (F) Fig. 53, to keep arbor from turning. Remove
screw (E) Fig. 52, out side blade flange (H) and blade (J).
DO NOT REMOVE INSIDE BLADE FLANGE.
5. Make sure the inside surfaces of both the inside and
out side blade flanges are clean and free from any
foreign subst ance.
6. Make sure the inside blade flange is completely on
the arbor with the flat s in the flange engaged with the
flat s on the arbor.
7.Inst all new blade (J) Fig. 52, out side blade flange
(H) and arbor screw (E). T urn arbor screw (E)
counterclockwise to tighten while pressing in on arbor
lock (F) Fig. 53, to keep arbor from turning.
IMPORTANT:Make sure flat s in out side blade flange
(H) Fig. 52, are engaged with flat s on arbor shaf t and that teeth of saw blade (J) are pointing down at the front,
as shown in Fig. 52.
8. Rot ate arbor cover (C) Fig. 51, until hook in cover is engaged under screw (B) and tighten screw (B) which
was loosened in STEP 2.
BRUSH INSPECTION AND REPLACEMENT
CAUTION: BEFORE INSPECTING BRUSHES, DISCONNECT THE MACHINE FROM THE POWER
SOURCE.
Brush life varies. It depends on the load on the motor. Check the brushes af ter the first 100 hours of use for a new
machine, or af ter a new set of brushes has been inst alled.
Af ter the first check, examine them af ter about 10 hours of use until such time that replacement is necessary.
The brush holders (A) Fig. 54, are located on the motor housing opposite each other. Fig. 55, illustrates one of
the brushes removed for inspection. When the carbon on either brush (B) is worn to
3
16" in length or if either
spring or shunt wire (C) is burned or damaged in any way, replace both brushes. If the brushes are found
serviceable af ter removing, reinst all them in the same position as removed.
Fig. 53
F
Fig. 54 Fig. 55
B
A
C
Page view 16